Verified Engineering EngineInteractive 2D Schematic

Jesmonite AC730 (Stone Casting) for Rectangular Mold Box Calculator

Pre-loads specific gravity (1.85) and 5:1 mix ratio to calculate exact Part A & Part B weights with cup scraping buffer.

Calculated Benchmark Answer

A standard Rectangular Mold Box (15 × 10 × 6 cm minus 150 cm³ master) requires 1499g (52.86 oz / 3.3 lbs) of Jesmonite AC730 (Stone Casting). Mix 1248.8g Part A with 249.8g Part B (8% buffer included).

Casting Material & Volume Mode

SG: 1.85

Pre-loads specific gravity and 5:1 ratio by weight.

box

Geometry determines the container-volume formula. Use water displacement when the cavity is irregular.

cm(5.9 in)
Min: 2 cm22%Max: 60 cm
cm(3.9 in)
Min: 2 cm17%Max: 50 cm
cm(2.4 in)
Min: 1 cm17%Max: 30 cm
cm³(5.1 fl oz)
Min: 0 cm³3%Max: 5000 cm³

Volume displaced by your master object inside the box.

%
Min: 0 %40%Max: 20 %

Compensates for resin clinging to mixing paddles and cup walls (8% recommended).

Preset Values: Buffer Presets
Graduated Mix Volume Schematic
RATIO 5:1
25%50%75%100%PART A [BASE]1249g44.05 oz+25%50%75%100%PART B [CATALYST]250g8.81 oz
PART A: 1248.8gJesmonite AC730 (Stone Casting)PART B: 249.8g
Mold Cavity Cross-Section
NET POUR: 750 cm³
MASTER OBJECT-150 cm³ Displaced1.5cm Wall1.5cm WallContainment: 15cm L × 10cm W × 6cm H
COMPOUND: Jesmonite AC730 (Stone Casting)•MASTER: 150 cm³•POUR: 750 cm³
Total Batch RequiredKEY RESULT
1498.5grams
52.86 oz (3.3 lbs)

Includes 8% waste buffer at SG 1.85

Part A (Base)
1248.8g
44.05 oz

Ratio part: 5

Part B (Catalyst)
249.8g
8.81 oz

Ratio part: 1

Mold Cavity Volume
750cm³ / mL
25.36fl oz

Net volume before buffer

Verified Casting Kit Reference Spec

Order Jesmonite AC730 (Stone Casting) Kit

High-tear strength Jesmonite AC730 (Stone Casting) with verified 5:1 ratio. Ideal for bubble-free casting.

Check Amazon StockSearch reference

Jesmonite AC730 (Stone Casting) vs Alternative Casting Compounds

Compare specific gravities, mix ratios, working times, and cure speeds across casting compounds.

Material / SpecificationSpecific GravityMix RatioPot LifeDemold Time
Jesmonite AC730 (Stone Casting)ACTIVE1.855:1 (weight)15 min4 hrs
RTV-2 Platinum Silicone (Smooth-On Mold Star 15/30)1.071:1 (weight)30 min6 hrs
RTV-2 Tin Cure Silicone (Condensation Cure)1.1210:1 (weight)45 min12 hrs
Jesmonite AC100 (Eco-Resin)1.752.5:1 (weight)12 min2 hrs
Deep Pour River Epoxy (2:1 Ratio)1.112:1 (weight)90 min48 hrs
Table Top & Art Epoxy (1:1 Ratio)1.081:1 (weight)25 min12 hrs

Step-by-Step Mix Ratio Derivation: Jesmonite AC730 (Stone Casting)

How displacement volume, specific gravity, and ratio split combine into final scale weights.

Step 1: Calculate Net Mold Cavity Volume750 cm³ (mL)
Formula: V_net = (L × W × H)_box - V_master
Calculation: (15 × 10 × 6) - 150 cm³ = 750 cm³ (mL)

Calculates the empty fluid cavity by taking the gross 900 cm³ box containment volume and deducting the 150 cm³ displaced by the master model.

Step 2: Calculate Total Batch Weight with 8% Buffer1498.5 grams
Formula: W_batch = V_net × SG × (1 + Buffer_pct / 100)
Calculation: 750 cm³ × 1.85 × 1.08 = 1498.5 grams

Multiplies fluid volume by the specific gravity of Jesmonite AC730 (Stone Casting) (1.85 g/cm³) plus an 8% buffer for cup scraping and pouring loss.

Step 3: Divide into Part A and Part B by Mix RatioPart A: 1248.8g | Part B: 249.8g
Formula: W_A = W_batch × (R_A / (R_A + R_B))
Calculation: 1498.5g × (5 / 6) = Part A: 1248.8g | Part B: 249.8g

Distributes batch mass according to the exact 5:1 ratio by weight.

MetriFab Precision GuaranteeFormulas cross-verified against Blum, Smooth-On, Polymaker, and eSun technical data sheets.
Zero-Lag SSG

Engineering Specifications & Troubleshooting Guide: Jesmonite AC730 (Stone Casting)

Factory-tested parameters, common failure modes, and workbench best practices.

Maker Pro Tips
  • Formulated with decorative stone aggregates for outdoor architectural facades and garden planters.
  • Acid-etch the cured surface with 5% brick acid or vinegar to expose shimmering granite/sandstone aggregates.
Most Critical Mistake to Avoid

Allowing direct outdoor water exposure before the complete 7-day moisture cure is achieved.

Recommended Machine Settings
mixing TechniqueMechanical paddle mixer; fold slowly to preserve aggregate texture.
degassing RequiredNo
demold NoteDemold after 4 hours. Keep under plastic wrap for 24 hours to cure.

Frequently Asked Questions: Jesmonite AC730 (Stone Casting)

Mix ratios, degas guidelines, cure times, and mold making tips.

Q1What is the mix ratio of Jesmonite AC730 (Stone Casting)?
Jesmonite AC730 (Stone Casting) has a mix ratio of 5 Part A to 1 Part B by weight. Always weigh both components on a digital scale for maximum cure integrity.
Q2How much Jesmonite AC730 (Stone Casting) do I need for a Rectangular Mold Box?
For a standard Rectangular Mold Box with 15 × 10 × 6 cm outer containment, you will need approximately 1499 grams (1248.8g Part A and 249.8g Part B) including an 8% waste buffer.
Q3How long before I can demold Jesmonite AC730 (Stone Casting)?
Jesmonite AC730 (Stone Casting) has a pot life (working time) of 15 minutes and can safely be demolded in 4 hours at room temperature (23°C / 73°F).