Verified Engineering EngineInteractive 2D Schematic

RTV-2 Tin Cure Silicone (Condensation Cure) for Hemisphere / Dome Mold Calculator

Pre-loads specific gravity (1.12) and 10:1 mix ratio to calculate exact Part A & Part B weights with cup scraping buffer.

Calculated Benchmark Answer

A standard Hemisphere / Dome Mold (Ø10 cm minus 150 cm³ master) requires 135g (4.77 oz / 0.3 lbs) of RTV-2 Tin Cure Silicone (Condensation Cure). Mix 122.9g Part A with 12.3g Part B (8% buffer included).

Casting Material & Volume Mode

SG: 1.12

Pre-loads specific gravity and 10:1 ratio by weight.

hemisphere

Geometry determines the container-volume formula. Use water displacement when the cavity is irregular.

cm(3.9 in)
Min: 2 cm17%Max: 50 cm
cm³(5.1 fl oz)
Min: 0 cm³3%Max: 5000 cm³

Volume displaced by your master object inside the box.

%
Min: 0 %40%Max: 20 %

Compensates for resin clinging to mixing paddles and cup walls (8% recommended).

Preset Values: Buffer Presets
Graduated Mix Volume Schematic
RATIO 10:1
25%50%75%100%PART A [BASE]123g4.34 oz+25%50%75%100%PART B [CATALYST]12g0.43 oz
PART A: 122.9gRTV-2 Tin Cure Silicone (Condensation Cure)PART B: 12.3g
Total Batch RequiredKEY RESULT
135.2grams
4.77 oz (0.3 lbs)

Includes 8% waste buffer at SG 1.12

Part A (Base)
122.9g
4.34 oz

Ratio part: 10

Part B (Catalyst)
12.3g
0.43 oz

Ratio part: 1

Mold Cavity Volume
111.8cm³ / mL
3.78fl oz

Net volume before buffer

Verified Casting Kit Reference Spec

Order RTV-2 Tin Cure Silicone (Condensation Cure) Kit

High-tear strength RTV-2 Tin Cure Silicone (Condensation Cure) with verified 10:1 ratio. Ideal for bubble-free casting.

Check Amazon StockSearch reference

RTV-2 Tin Cure Silicone (Condensation Cure) vs Alternative Casting Compounds

Compare specific gravities, mix ratios, working times, and cure speeds across casting compounds.

Material / SpecificationSpecific GravityMix RatioPot LifeDemold Time
RTV-2 Tin Cure Silicone (Condensation Cure)ACTIVE1.1210:1 (weight)45 min12 hrs
RTV-2 Platinum Silicone (Smooth-On Mold Star 15/30)1.071:1 (weight)30 min6 hrs
Jesmonite AC100 (Eco-Resin)1.752.5:1 (weight)12 min2 hrs
Jesmonite AC730 (Stone Casting)1.855:1 (weight)15 min4 hrs
Deep Pour River Epoxy (2:1 Ratio)1.112:1 (weight)90 min48 hrs
Table Top & Art Epoxy (1:1 Ratio)1.081:1 (weight)25 min12 hrs

Step-by-Step Mix Ratio Derivation: RTV-2 Tin Cure Silicone (Condensation Cure)

How displacement volume, specific gravity, and ratio split combine into final scale weights.

Step 1: Calculate Net Mold Cavity Volume111.8 cm³ (mL)
Formula: V_net = (2 / 3) × π × (D / 2)³ - V_master
Calculation: (2 / 3) × π × (10 / 2)³ - 150 cm³ = 111.8 cm³ (mL)

Calculates the empty fluid cavity by taking the gross 261.8 cm³ hemisphere containment volume and deducting the 150 cm³ displaced by the master model.

Step 2: Calculate Total Batch Weight with 8% Buffer135.2 grams
Formula: W_batch = V_net × SG × (1 + Buffer_pct / 100)
Calculation: 111.8 cm³ × 1.12 × 1.08 = 135.2 grams

Multiplies fluid volume by the specific gravity of RTV-2 Tin Cure Silicone (Condensation Cure) (1.12 g/cm³) plus an 8% buffer for cup scraping and pouring loss.

Step 3: Divide into Part A and Part B by Mix RatioPart A: 122.9g | Part B: 12.3g
Formula: W_A = W_batch × (R_A / (R_A + R_B))
Calculation: 135.2g × (10 / 11) = Part A: 122.9g | Part B: 12.3g

Distributes batch mass according to the exact 10:1 ratio by weight.

MetriFab Precision GuaranteeFormulas cross-verified against Blum, Smooth-On, Polymaker, and eSun technical data sheets.
Zero-Lag SSG

Engineering Specifications & Troubleshooting Guide: RTV-2 Tin Cure Silicone (Condensation Cure)

Factory-tested parameters, common failure modes, and workbench best practices.

Maker Pro Tips
  • Immune to cure inhibition from sulfur clays and UV 3D resins; ideal when making molds of photopolymer resin 3D prints.
  • Has slightly higher linear shrinkage (0.2% - 0.4%) than platinum cure.
  • Measure Part B on a precision gram scale (0.1g accuracy) because the 10:1 ratio is sensitive to catalyst ratios.
Most Critical Mistake to Avoid

Eyeballing Part B catalyst; adding too much causes brittleness, too little leaves the silicone permanently tacky.

Recommended Machine Settings
mixing TechniqueMix slowly with a flat-blade paddle for 3 full minutes.
degassing RequiredNo
demold NoteLeave undisturbed for 12 hours. Do not flex mold until full 24-hour cure is achieved.

Frequently Asked Questions: RTV-2 Tin Cure Silicone (Condensation Cure)

Mix ratios, degas guidelines, cure times, and mold making tips.

Q1What is the mix ratio of RTV-2 Tin Cure Silicone (Condensation Cure)?
RTV-2 Tin Cure Silicone (Condensation Cure) has a mix ratio of 10 Part A to 1 Part B by weight. Always weigh both components on a digital scale for maximum cure integrity.
Q2How much RTV-2 Tin Cure Silicone (Condensation Cure) do I need for a Hemisphere / Dome Mold?
For a standard Hemisphere / Dome Mold with Ø10 cm outer containment, you will need approximately 135 grams (122.9g Part A and 12.3g Part B) including an 8% waste buffer.
Q3How long before I can demold RTV-2 Tin Cure Silicone (Condensation Cure)?
RTV-2 Tin Cure Silicone (Condensation Cure) has a pot life (working time) of 45 minutes and can safely be demolded in 12 hours at room temperature (23°C / 73°F).